BidRidge › Designers › Guide › Chapter 36

Chapter 36 · Roofing & Siding DesignerBeta

Sample Hotel, 4 stories: EIFS with grooves and a foam cornice, fiber cement lap and panel siding, porcelain panels at the entry

From the designer's third commercial sample: a 140 x 60 ft, 4-story wood-frame hotel (Type V-A). A drainage EIFS base with V grooves checked against the board thickness, a stepped foam cornice and sloped foam sills checked for their wash slope, and impact mesh at the entry; fiber cement lap and panel siding on the floors above, with band boards at the floor lines and flashed transitions between the claddings; porcelain rainscreen panels on rails at the entry. The checks with their sources, the NFPA 285 and combustibility flags the same walls would get on a Type I to IV building, the order list and the Submittal set.

In the Roofing & Siding Designer, tap Open project and pick the sample file: it opens as the hotel in this chapter.

Narrated walkthrough, 1:54. Captions on.

The sample in numbers

  • Cladding
    15,800 sf
    EIFS 3,671 · lap 7,291 · panel 4,674 · porcelain 164
  • Grooves
    1,319 LF
    3/4 x 3/4 in. V, 1 1/4 in. of board left
  • Foam shapes
    462 LF
    372 LF stepped cornice · 90 LF sloped sills
  • Siding
    1,049 pcs
    lap, + 160 panel sheets · 800 LF of band boards
  • Rainscreen
    26 panels
    87 LF of rails · 104 concealed clips
  • Sheets
    27
    Submittal set, 11x17 shop (22 on ARCH D)

Step by step

Step 1: Open the hotel sample in the Roofing & Siding Designer

Step 1: Open the hotel sample

Open the Roofing & Siding Designer, tap New design, then Sample Hotel, 4 stories, EIFS and siding. The project type is Commercial. On W3, the south wall, the first floor is EIFS (EF-1, 1,032 sf on this wall) with its grooves, the floors above fiber cement lap siding either side of a panel-siding bay, and the entry porcelain panels (PC-1, 164 sf) with their marks. Gridlines, levels and the zone 5 corner bands are drawn on every elevation.

Field tip: The sample's names and sizes are made up. The Groove across, Groove up, Band and Cornice tools are on the wall toolbar.

Step 2: The cladding systems in the Roofing & Siding Designer

Step 2: The cladding systems

Cladding systems: EF-1 drainage EIFS over the WRB on 2 in. EPS with 3/4 x 3/4 in. V grooves 24 in. apart and a medium sand finish (3,671 sf); LS-1 fiber cement lap siding at a 7 in. exposure (7,291 sf); PS-1 fiber cement panel siding in 4 ft sheets (4,674 sf); PC-1 porcelain panels 24 x 48 in. with 1/4 in. open joints on the opening lines, on concealed clips and rails (164 sf).

Field tip: Generic systems: the products come from the specification; the cladding list also has board and batten, shingle and vinyl siding, terracotta, wood and composite rainscreen boards and metal plank panels.

Step 3: The wall assemblies in the Roofing & Siding Designer

Step 3: The wall assemblies

Behind the cladding, on 2x6 wood studs and 1/2 in. plywood: WA-1 (W1 and W3, 10,850 sf) has a fluid-applied air and water barrier with the cladding fastened direct; WA-2 (W2 and W4, 4,950 sf) adds 1 1/2 in. of mineral wool (R-6.3 nominal) under hat channels 16 in. apart.

Field tip: The same Wall assemblies as chapter 34: each wall picks one, the details draw it.

Step 4: EIFS: drainage or barrier, impact mesh in the Roofing & Siding Designer

Step 4: EIFS: drainage or barrier, impact mesh

EIFS systems: EF-1 is a drainage EIFS over the WRB (barrier EIFS is the other choice), 2 in. EPS set in adhesive. The designer adds the heavy-duty impact mesh under the standard mesh to 6 ft above grade and around the entry (2,004 sf), 372 LF of starter track, 1,143 LF of detail mesh to back-wrap every termination and 82 diagonal pieces at the opening corners.

Field tip: The impact mesh height is a typical figure (none was read in a code or standard): set the project's.

Step 5: Grooves and foam shapes in the Roofing & Siding Designer

Step 5: Grooves and foam shapes

EIFS grooves: G1, horizontal V grooves 3/4 x 3/4 in., 1,319 LF, leave 1 1/4 in. of the 2 in. board, against the 3/4 in. minimum (ASTM E2511, 6.1.9). EIFS shapes, drawn with the Band and Cornice tools: C1, an 18 x 8 in. stepped cornice in 3 steps (372 LF, 2,480 board ft, 959.3 sf of girth to mesh and finish) and S1, a 4 x 3 in. sloped sill (90 LF). Each shape's top is checked for its wash slope: 1:2 (6:12) here.

Field tip: Cornices, sills, surrounds, quoins and keystones are generic profiles under EIFS shapes and defaults: edit the sizes or add your own.

Step 6: The EIFS, siding and panel checks in the Roofing & Siding Designer

Step 6: The EIFS, siding and panel checks

The checks pass the groove depth against the board (ASTM E2511-17) and note the rest with their sources: keep the EPS board joints off the groove lines, the impact mesh, back-wrapping and diagonal mesh with the sealant on the base coat (UFGS 07 24 00), the porcelain's open joints in front of a barrier listed for open-joint cladding, and 504 LF and 296 LF of floor-line band boards with Z-flashing for wood shrinkage (WoodWorks).

Field tip: Each check names its source: the ASTM guide, the federal EIFS guide specification, the IBC sections or the wood shrinkage guide.

Step 7: NFPA 285 and combustibility flags in the Roofing & Siding Designer

Step 7: NFPA 285 and combustibility flags

The hotel is Type V-A, so it gets no NFPA 285 flags. Set the same walls on a Type IIIA building and three appear: the combustible WRB over 40 ft on WA-1 and WA-2 (IBC 2021 1402.5) and the EIFS itself, a foam plastic, at any height (2603.5, 2603.5.5, with the foam's flame spread and smoke indexes and the NFPA 268 test). On Types I to IV, combustible siding (wood, vinyl, combustible composites) is flagged above 40 ft and past 10% of a wall at a fire separation distance of 5 ft or less (1405.1.1); fiber cement gets none.

Field tip: Flags to review with the design team, never a finding that a wall complies.

Step 8: Siding on commercial walls and transitions in the Roofing & Siding Designer

Step 8: Siding on commercial walls and transitions

Siding systems: LS-1 is 1,049 pieces 12 ft long (12,522.5 LF of courses) with 1,080 LF of 5/4x4 casing and 60 LF of corner boards, and 504 LF of band boards at the floor lines; PS-1 is 160 sheets 4 x 10 ft with its casing, corner boards and 296 LF of band boards. Transitions between claddings: Z-flashing over the EIFS where siding sits above it (backwrapped, sealant under it), a Z-flashing with a drip where panel siding sits over the porcelain, and trim or a backwrapped sealant joint at each vertical joint.

Field tip: Lap, panel, board and batten and shingle siding use the residential siding layout, so the courses, sheets and trims are the same engine.

Step 9: Rainscreen panels on rails in the Roofing & Siding Designer

Step 9: Rainscreen panels on rails

Rainscreen rails and clips: the porcelain panels at the entry are laid out on the opening lines with open joints and hung on concealed clips on rails: 87 LF of rails and 104 clips for 164 sf. Terracotta runs in horizontal courses on rails, wood and composite rainscreen boards in runs with their board width and open gap, and metal plank panels in runs, each with its rails, clips and details.

Field tip: Clips and rails per the panel maker's tested attachment; terracotta adds baguettes and sunscreens by the LF.

Step 10: The order list in the Roofing & Siding Designer

Step 10: The order list

Order list: for the EIFS, 482 boards of 2 in. EPS 2 x 4 ft (9,895.1 board ft with the shapes), 98 pails of base coat, 42 pails of finish and 9 + 7 rolls of mesh; for the siding, 1,049 lap pieces and 160 panel sheets; for the porcelain, 26 panels cut from 5 sheets 63 x 126 in. (41.3% waste with the joints on the openings, 39.9% without). Send to BidRidge carries the EIFS as its own EIFS scope and the siding and panels as commercial answers on the Siding scope.

Field tip: EIFS quantities follow the EIFS maker's coverages; grooves and shapes are in the girth.

Step 11: The Submittal set in the Roofing & Siding Designer

Step 11: The Submittal set

Drawing set, Sheets for: Submittal set. The 11x17 shop set has 27 sheets: the cover, seven sheets of typical details (each wall assembly with each cladding, the base, parapet and coping, counterflashing, window heads, sills and jambs, penetrations, the canopy soffit, the EIFS base with its starter track, the EIFS head and jamb, the groove section and the sloped foam sill), the four elevations, then the cladding systems, assemblies, EIFS systems, grooves and shapes, siding systems, transitions and the rest of the schedules. On ARCH D the full set has 22.

Field tip: The Submittal set is download only: Save PDF. It is never added to the BidRidge job.

What you get

The drawing set, the lists and the files

Real files from this sample, made by the designer. Tap a page to see it full size. Yours carry your company, the client and the address.

Submittal (ARCH D) R-0 Cover sheet and sheet index
Submittal (ARCH D) R-0 Cover sheet and sheet index
R-3 Elevation W3 (ARCH D)
R-3 Elevation W3 (ARCH D)
R-20 Details (ARCH D)
R-20 Details (ARCH D)
R-1 Typical details: the wall assemblies with each cladding
R-1 Typical details: the wall assemblies with each cladding
R-2 Typical details (cont.): base, parapet and coping, counterflashing
R-2 Typical details (cont.): base, parapet and coping, counterflashing
R-3 Typical details (cont.): openings, penetration, canopy, EIFS base
R-3 Typical details (cont.): openings, penetration, canopy, EIFS base
R-4 Typical details (cont.): EIFS head, jamb, groove and sloped sill
R-4 Typical details (cont.): EIFS head, jamb, groove and sloped sill
R-15 EIFS grooves
R-15 EIFS grooves
R-16 EIFS shapes
R-16 EIFS shapes

More in the guide

Try it on your own job

Open the sample, change it to your measurements, and send it to a BidRidge quote. Drawing is free; the drawing set, the lists and the quote come with a BidRidge license or the 14-day trial.

In the Roofing & Siding Designer, tap Open project and pick the sample file: it opens as the hotel in this chapter.

Sample designs: names, sizes and clients are made up. Prices are BidRidge's starting rates; set your own. The designers check against common guidelines (IRC, NKBA and the makers' published numbers) to help you catch mistakes. They don't replace your building department or the manufacturer's installation instructions: verify with them.