Metal: every plane against the profile's minimum slope; flashing legs at least the rib height + 1″; ribs over 1 1/4″ get high-rib trims and Z-closures. Shingles: 2:12 minimum, two layers of underlayment under 4:12. Ice barrier (Alaska rule): from the eave edge to 24″ inside the warm wall in whole 36″ courses, 36″ in every valley. Code figures are defaults to verify with your building department.
Siding: every opening fits its wall and nothing overlaps; windows clear the lines with transition trim; fixtures sit on the siding. EIFS: drainage EIFS over framed walls (IRC R703.9.2), clearances above grade, paving and roofs, impact mesh at grade; verify with the EIFS maker and your building department.
Every place two assemblies meet, with its profile, metal and gauge. Gauges are checked against the code minimum (a default: verify with your building department); metals that don't go together are flagged. On-site rows are clearances to keep on site.
NFPA 285 flags from the IBC 2021 model text (1402.5 combustible water-resistive barriers over 40 ft, 1406.10 MCM, 1408.10 HPL, 2603.5 foam plastic insulation on Types I to IV): the walls that usually need a tested assembly. Flags to review with the design team, never a finding that a wall complies. Wind zone 5 width from the ASCE 7-16 chapter 30 wall-zone rule (h up to 60 ft); attachment spacing per zone is yours, from the cladding maker's tested attachment tables; past them, the engineer to confirm. Details are typical, not engineered: install per the makers' instructions.
Makes a template with a Roofing scope: one roof report row per section (type, sloped area, pitch, tear-off, eaves, rakes, ridges, hips, valleys, wall flashing, steep area, ice barrier sf and metal trim LF), plus the job answers, a notes block and the drawing set, cut list and buy list. BidRidge prices it at your rates.
Makes a template with a Siding scope: one wall row per wall or siding section with its openings, corners and trim, one eave row per eave or rake run with soffit, fascia, gutters and downspouts, plus the job answers, a notes block and the drawing set, cut list and buy list. BidRidge prices it at your rates. EIFS sections go as their own EIFS scope (BidRidge's EIFS trade): one row per EIFS section with its system, foam, finish, mesh, bands, reveals, quoins and sealant.
Makes a template with a Roofing scope (one roof report row per section: type, sloped area, pitch, tear-off, eaves, rakes, ridges, hips, valleys, wall flashing, steep area, ice barrier sf and metal trim LF) and a Siding scope (one wall row per wall with its openings and corners, one eave row per eave or rake run with soffit, fascia, gutters and downspouts), plus the job answers, a notes block and the drawing set, cut list and buy list. BidRidge prices them at your rates. EIFS sections go as their own EIFS scope (BidRidge's EIFS trade): one row per EIFS section with its system, foam, finish, mesh, bands, reveals, quoins and sealant.
Open in BidRidge hands the template to the BidRidge web app in this browser (bid-ridge.com/app) and opens its Templates screen. For the Android app, use Save BidRidge template and import the file.
One row a product the design uses, under its MasterFormat section (07 42 13, 07 27 00, 07 92 00...). Generic: type the product and manufacturer the specification calls for.