BidRidge › Designers › Guide › Chapter 41

Chapter 41 · Metal Stud & Drywall DesignerBeta

Sample Office Floor, steel stud partitions: 10 partitions, 292 LF, 4 types (A corridor 1-hr to the deck, B office to the ceiling + 6 in., C restroom, S 2-hr shaft wall), a soffit, restroom backing; and the Sample Medical Clinic: 19 partitions, 389 LF, exterior walls with a fluid-applied barrier and 2 in. of mineral wool, a 45-degree entry wall, an L-shaped, a curved and a stepped soffit

New in 1.72: steel stud partitions have their own designer, the Metal Stud & Drywall Designer (before, they were the Steel partitions mode of the Rough Carpentry Designer). It draws the partition types from the drawings' schedule, the partitions on the plan with their openings, soffits of any shape (angled, L-shaped, curved, stepped trays), shaft walls and backing, the stud-by-stud takeoff and the checks. Exterior wall types are wind-load stud walls (structural studs, the wind pressure from the drawings, the deflection limit by the cladding, infill or bypass) with the sheathing, the water-resistive barrier and continuous insulation. The drawing set, the Submittal set and a priced quote for Rough carpentry, Drywall and Insulation come from the same design; Typical floors frames the plan again on other levels.

Narrated walkthrough, 1:49. Captions on.

The sample in numbers

  • Partitions
    292 LF
    10 partitions, 4 types; 247 full-height studs, 28 jambs, 20 cripples
  • Track
    484 LF
    plus 200 LF of deflection track at the deck
  • Board
    7,310 sf
    174 sheets with 10% waste; 448 sf of shaft liner
  • Checks
    0
    to fix; 1 to review (a 6 ft opening over the 4 ft header note), 8 notes
  • Sheets
    8
    drawing set, 11 x 17; Submittal 6 (ARCH D) or 8 shop sheets

Step by step

Step 1: Start here in the Metal Stud & Drywall Designer

Step 1: Start here

Open the Metal Stud & Drywall Designer. Start here offers Sample Office Floor (corridor walls 1-hr to the deck, offices to the ceiling, a restroom, a 2-hr elevator shaft, a corridor soffit), Sample Medical Clinic (exterior steel walls, a 45-degree entry wall, sink alcoves and three soffits of any shape) and Blank floor (one partition type; add yours from the schedule). Every design is Commercial. An older Rough Carpentry design with steel partitions shows a button that moves them here; the wood stays behind.

Field tip: The samples' names and sizes are made up; every product is generic.

Step 2: Enter the partition types in the Metal Stud & Drywall Designer

Step 2: Enter the partition types

Partition types holds one card a type from the drawings' partition schedule: tag, kind (partition, shaft wall, chase wall, furring), stud depth, thickness in mils and spacing, the board layers each side, cavity insulation, rating, STC as the schedule gives it, the top (to the deck with a slotted, deflection or double track head, or above the ceiling plus an extension), and the UL or GA design number as text.

Field tip: Stud sizes follow the industry designation (362S125-30): typical; verify with your supplier's data.

Step 3: Paste the schedule, or start from an assembly in the Metal Stud & Drywall Designer

Step 3: Paste the schedule, or start from an assembly

Paste the schedule rows (one type a line) and Read the schedule fills the tag, stud, gauge or mils, spacing, layers, rating, STC, design, top and insulation; check each type after. Type or pick a listed design (the IBC 2021 Table 721.1(2) items 13-1.1 and 13-1.2, read from the code, and UL U419, U465, U412, U435, U451 and the shaft walls U415, U417, U438, U467, U469, read in UL Product iQ) and the type takes its rating, layers and limits from the entry at its rating, and the editor says Listed with the date read and the ratings the design offers. Head-of-wall systems UL HW-D-0032, -0269, -0418 and -0908 are built in too. Other UL designs and GA design numbers stay as typed (GA-600 is a paid manual), and the editor says so. The generic 1-hr, 2-hr, shaft and furring makeups are typical and unverified.

Field tip: For a UL or GA design, type its own limits (max. spacing, min. stud) and the checks compare against them.

Step 4: Draw the partitions in the Metal Stud & Drywall Designer

Step 4: Draw the partitions

Pick the type above the plan, then Partition: tap each end; keep tapping to chain runs, Esc to stop. Ends that meet make a corner, an end on another run makes a T. Opening puts a door on a run (change it to a cased opening, window or pass-through in its panel), Soffit drags a soffit or bulkhead, Backing adds backing at the tap. Rated types draw with red dashes, shaft walls darker.

Field tip: Any field takes 12' 6", 150, 3.8m or 381cm.

Step 5: Each partition, stud by stud in the Metal Stud & Drywall Designer

Step 5: Each partition, stud by stud

Tap a partition: its type, length and height, the openings and the backing, and its framing elevation: studs on layout from the start at the spacing, jambs doubled per the type, a box header of track and stud, cripples above (and below a window), bridging rows, control joints moved to the door jambs.

Field tip: Each partition's flags show at the top of its panel.

Step 6: Backing and soffits in the Metal Stud & Drywall Designer

Step 6: Backing and soffits

Backing rows take grab bars, wall cabinets, TVs, handrails and accessories with their height and width; they print on the backing plan. Steel framing > Backing from a Division 10 design reads that designer's saved .json: each wall-mounted grab bar or accessory lands on the partition its wall lies on (draw both on the same plan); compartment items are counted for you to add. A soffit's panel takes its bottom height, hanger spacing and board; the faces along a partition are not wrapped (step 7 has soffits of any shape).

Field tip: Backing material (sheet steel plate, treated wood or strap) is set once in Steel framing.

Step 7: Soffits of any shape in the Metal Stud & Drywall Designer

Step 7: Soffits of any shape

Soffit drags a rectangle; Soffit, any shape taps the corners and closes on the first. In its panel each edge has its length, a curve (the rise from the straight line to the middle of the arc; plus bows out, minus in) and Remove corner. Drag a corner to move it; drag the dot in the middle of an edge to add a corner. Add a step inside draws a soffit 12 in. higher inside it: a tray. Where two soffits meet, the face is the step between their bottoms; a soffit inside another takes its area out of the outer one. The takeoff counts the plan area, the hangers, the bottom framing, the faces to wrap (to the Drywall trade) and the curved faces on their own line.

Field tip: Curved faces need bent or flexible track and flexible board: the bending radius comes from the board maker.

Step 8: Exterior walls: barrier and continuous insulation in the Metal Stud & Drywall Designer

Step 8: Exterior walls: barrier and continuous insulation

A type set to Exterior wall takes the wind pressure from the structural drawings, the cladding (it sets the deflection limit), infill or bypass at the slabs, and now the water-resistive barrier (sheet or fluid-applied) and continuous insulation (thickness and board: XPS, polyiso or mineral wool) over the sheathing. The barrier and insulation are counted on the wall face less the openings; the cavity batts and the continuous insulation go to the Insulation trade as their own rows. An exterior wall with no barrier is flagged (IBC 1403.2).

Field tip: Fasteners and cladding attachment through the continuous insulation are per the engineer and the cladding maker.

Step 9: Set the job's heights and spacings in the Metal Stud & Drywall Designer

Step 9: Set the job's heights and spacings

Steel framing in the side panel: the deck and ceiling heights, the deflection limit (L/120 flexible, L/240 brittle, L/360 plaster or stucco), the lateral load (5 psf minimum), stud stock lengths or cut-to-length, the deflection gap, control joints (30 ft typical), bridging (48 in. typical), PAFs, braces, board screws, corner and T studs, the lift height, firestopping by you or others.

Field tip: Every spacing is a typical starting value: use the project's specifications and the listed designs.

Step 10: Read the checks in the Metal Stud & Drywall Designer

Step 10: Read the checks

Flags, never a certification: studs taller than the allowable height (from the SFIA Technical Guide's interior limiting-height tables for the stud, spacing, load and deflection limit, composite only when the board is full height on both sides and fastened at the head; else your supplier's value), no deflection head under a deck, a rated wall at the deck with a deflection head and no head-of-wall joint system (IBC 2021 715.3), the type against a listed design (spacing, stud, layers, insulation, resilient channel, rating), a listed head-of-wall system against the wall (rating, the walls it is listed with, movement against the head gap, stud depth, shaft or partition), a rated wall that stops at a ceiling (707.5, 708.4), a shaft wall under its rating for the stories it connects (713.4), a load under 5 psf (1607.16), an opening wider than the header note, a shaft wall without its liner.

Field tip: A stud with no table row (EQ studs, 19.2 in. spacing) asks for your supplier's height instead of guessing.

Step 11: The takeoff in the Metal Stud & Drywall Designer

Step 11: The takeoff

Steel takeoff lists the type schedule, then studs nested into the stock lengths with the waste, track and deflection track, openings, bridging and bracing, furring, soffits, shaft wall CH studs and liner panel, backing, control joints, fasteners at the spacings typed, board by kind and sheet length, corner bead, insulation, head-of-wall joints and lift days.

Field tip: Board sheets come from each wall's board height: 8, 9, 10 or 12 ft, stacked above 12 ft.

Step 12: Drawings, Submittal and the quote in the Metal Stud & Drywall Designer

Step 12: Drawings, Submittal and the quote

Drawing set > Steel framing sheets adds the partition framing plan with tags, the type schedule, the type sections (head at the deck, head above the ceiling, base, corner, T, door jamb and header, control joint, soffit, shaft wall), wall elevations and the backing plan. Sheets for > Submittal set makes the review set with product data under 05 40 00, 09 22 16, 09 21 16 and 07 84 43 (verify against your project manual). Send to BidRidge sends Rough carpentry (the Steel framing lines), Drywall (board by type and layer) and Insulation (batts, head-of-wall joints) as a commercial job.

Field tip: The Submittal set and the steel sheets come with BidRidge Commercial; Education and trials see them too.

Step 13: Plan background: draw over the floor plan

Open the Plan background section and import the floor plan (a PDF page or a photo of it). Tap Set scale, click both ends of a long dimension and type it; Check it on a second one. Your drawing tools now snap to the plan's corners and lines. Trace walls adds partitions in the type whose drawn thickness is nearest the traced one, and Trace room puts partitions around a room. On a vector PDF with the scale set, Suggest walls finds the walls from the drawing's double lines and shows them for review; tap any you don't want, then Use adds the rest. Scanned sheets are traced by hand. The plan is saved with the design (with Save project, its picture too) and never prints.

What you get

The drawing set, the lists and the files

Real files from this sample, made by the designer. Tap a page to see it full size. Yours carry your company, the client and the address.

FR-1 Partition framing plan
FR-1 Partition framing plan
FR-2 Partition type schedule
FR-2 Partition type schedule
FR-4 Partition type sections
FR-4 Partition type sections
FR-7 Wall framing elevations
FR-7 Wall framing elevations
FR-8 Backing plan
FR-8 Backing plan
Submittal (ARCH D) FR-1 Partition plan and notes
Submittal (ARCH D) FR-1 Partition plan and notes
Submittal (11x17 shop) FR-4 Type A: Corridor wall, 1-hr to deck
Submittal (11x17 shop) FR-4 Type A: Corridor wall, 1-hr to deck
The Sample Medical Clinic: exterior walls (E), the 45-degree entry, an L-shaped, a curved and a stepped soffit
The Sample Medical Clinic: exterior walls (E), the 45-degree entry, an L-shaped, a curved and a stepped soffit

More in the guide

Try it on your own job

Open the sample, change it to your measurements, and send it to a BidRidge quote. Drawing is free; the drawing set, the lists and the quote come with a BidRidge license or the 14-day trial.

Sample designs: names, sizes and clients are made up. Prices are BidRidge's starting rates; set your own. The designers check against common guidelines (IRC, NKBA and the makers' published numbers) to help you catch mistakes. They don't replace your building department or the manufacturer's installation instructions: verify with them.