BidRidge › Designers › Guide › Chapter 29

Chapter 29 · Tile DesignerBeta

Sample hotel: large-format tile, panels and transitions

The tile systems of the same sample hotel: a lobby in 24 x 48 large-format tile laid out from a level line, a feature wall of gauged porcelain panels, grout types, a sound mat under the guest baths, the submittal extras, the floor heights and the transition at every door, and setter and finisher crews in the BidRidge quote.

In the Tile Designer, tap Open project and pick the sample file, or tap Open the sample hotel on the Building plan card: it is the same job.

Narrated walkthrough, 1:48. Captions on.

The sample in numbers

  • Large-format
    612 sf
    FT-1 (typical) and FT-4: a side 15 in. or more
  • Panels
    7
    WT-P 39 3/8 × 118 1/8 · 5 full, 2 cut · 196.9 sf
  • Level line
    48″ AFF
    dashed on every wall elevation
  • Sound mat
    192 sf
    ANSI A118.13, its rating typed from its data
  • Doors
    7
    2 flush · 1 vertical · 4 beveled (ADA 303)
  • Setting hours
    426 h
    by crew productivity (360 h by the rate book)

Step by step

Step 1: Tile kind on the finish code in the Tile Designer

Step 1: Tile kind on the finish code

In the Finish schedule, Tile kind makes a code large-format (By size: a side of 15 in. or more, as FT-1 and FT-4) or Gauged porcelain tile / panel (ANSI A137.3, 1 m² or larger: WT-P). Large tile and panels get their notes once a code, and panels are marked on their views.

Step 2: Lippage, flatness and coverage in the Tile Designer

Step 2: Lippage, flatness and coverage

The full set's TILE SYSTEMS notes give, a code: the lippage limit (1/32 in. under 1/4 in. joints plus the tile's warpage; panels 1/32 in.), substrate flatness (1/8 in. in 10 ft and 1/16 in. in 24 in.), mortar coverage (80% dry, 95% wet, corners supported) and back-buttering with an LHT mortar.

Field tip: Running bond with a side over 18 in. checks the joint width (ANSI A108.02 4.3.8.1).

Step 3: The level line in the Tile Designer

Step 3: The level line

Under Large tile, panels and level line, type the level line in inches above the finished floor: 48 here. It is dashed on every wall elevation of the Submittal set (LEVEL LINE 48″ AFF) and in the notes: snap it level around the room, lay out the courses and panel joints from it.

Field tip: A job with large tile or panels and no level line gets a check asking for one.

Step 4: Gauged porcelain panels in the Tile Designer

Step 4: Gauged porcelain panels

The lobby's feature wall is WT-P, 39 3/8 x 118 1/8 in. panels. Each piece is marked P1 to P7 on the elevation and the cut ones are listed with their sizes (5 full, 2 cut), with the handling notes, the A108.19 installation and the gauged porcelain panel detail.

Step 5: Grout types in the Tile Designer

Step 5: Grout types

Grout type on a code says which grout it is: cement (ANSI A118.6), high-performance cement (A118.7, FT-4 here), epoxy (A118.3, QT-1), modified epoxy emulsion (A118.8) or furan (A118.5), each with its installation standard, on the finish schedule, the finish lines and the product log.

Field tip: Epoxy grout goes to BidRidge on the epoxy grout upgrade line.

Step 6: Sound-control membranes in the Tile Designer

Step 6: Sound-control membranes

The Level 2 guest baths are on FT-1 with a Sound-control membrane (ANSI A118.13) and its Sound rating typed from the product data (the sample's rating is made up). The finish line, the product log and the floor detail on a sound-control membrane carry it; BidRidge gets the sound mat sf.

Field tip: There is no default rating: a blank one is asked for.

Step 7: Submittal extras and extra stock in the Tile Designer

Step 7: Submittal extras and extra stock

Submittal extras lists the ANSI A137.1 Master grade certificate for each tile in the product log, and your Installer qualifications (Use the example names CTEF's CTI and ACT) and System warranty, printed on the cover. Extra stock is set a code in the Finish schedule (2%, 3 boxes, 24 pcs) and added to the buy list.

Step 8: Floor heights in the Tile Designer

Step 8: Floor heights

Floor heights, doors and transitions works out each floor's finished height above its slab: tile + bond coat (1/8 in. here) or mortar bed + backer board + the code's membrane thickness. 201 Guest bath is 5/8 in.: 3/8 tile, 1/8 bond coat, 1/8 sound mat and membrane. A slab recessed under a room takes its height down.

Step 9: Doors and the transition schedule in the Tile Designer

Step 9: Doors and the transition schedule

Add each room's doors: to another tile room (its height computed) or another floor, typed or read from a Flooring Designer project. Each change in level is checked against the 2010 ADA Standards (303.2 vertical to 1/4 in., 303.3 beveled 1:2, 303.4 ramped) with the transition it needs. Here: 2 flush, 1 vertical 1/8 in., 4 beveled. The Building plan's Door tool (or the door's Wall and From corner fields) places a door on the room plans; the sample's doors are not placed, and each room sheet says so.

Field tip: The full set gets the TRANSITION SCHEDULE; the buy list the strips, by the foot.

Step 10: Setter and finisher crews in the Tile Designer

Step 10: Setter and finisher crews

Tick Price the tile setting in BidRidge by crew productivity. In BidRidge the job then asks for the setters and finishers in the crew and the sf a crew-day by tile size (mosaic, up to 12 in., 12 to 24 in., large format, panels: starting points to set yours), and the floor and wall setting hours come from the crew, room by room.

Field tip: A job that does not opt in prices from the rate book as before.

What you get

The drawing set, the lists and the files

Real files from this sample, made by the designer. Tap a page to see it full size. Yours carry your company, the client and the address.

T-12 100 Lobby: large-format floor, panel wall with the level line
T-12 100 Lobby: large-format floor, panel wall with the level line
T-9 100 Lobby (ARCH D full set)
T-9 100 Lobby (ARCH D full set)
T-1 Floor finish plan: Level 1 with the finish schedule (its DETAIL column), tile systems and transition schedule (ARCH D)
T-1 Floor finish plan: Level 1 with the finish schedule (its DETAIL column), tile systems and transition schedule (ARCH D)
T-2 Typical details (cont.): the gauged porcelain panel detail
T-2 Typical details (cont.): the gauged porcelain panel detail
T-10 Typical tile details (ARCH D): the cove base at full size, the edge trim
T-10 Typical tile details (ARCH D): the cove base at full size, the edge trim

The BidRidge quote

Same numbers in the quote

The designer sends its quantities to BidRidge, and BidRidge prices the labor and materials at your rates.

  • Good
    $123,300
  • Better
    $150,050
    Recommended
  • Best
    $218,200
The design and the quote, line by line
ItemIn the designerIn the BidRidge quote
Large-format tileFT-1 and FT-4, 612 sfLarge-format tile: handling, back-buttering, lippage 612 sf
PanelsWT-P, 196.9 sfGauged porcelain tile panels, install, 196.9 sf
Sound matFT-1 guest baths, 192 sfSound-control membrane 192 sf
Extra stocka code each (2%, boxes, pieces)Extra stock (attic stock) 121.9 sf
Transitions7 doorsTransition strips and thresholds 32.2 LF
CrewsPrice by crew productivity ticked1 setter and 1 finisher: 425.9 setting hours (360.4 by the rate book)

The sample hotel's template imported into a Tile job in the BidRidge app at its starting rates, crews on. It comes in as a commercial job (the commercial default, commercial open shop); on residential open shop: $88,300 / $111,250 / $172,300. The Submittal set is not part of it. Your rates give your own numbers. Without crew productivity (the rate book's hours): $119,700 / $146,250 / $214,250.

More in the guide

Try it on your own job

Open the sample, change it to your measurements, and send it to a BidRidge quote. Drawing is free; the drawing set, the lists and the quote come with a BidRidge license or the 14-day trial.

In the Tile Designer, tap Open project and pick the sample file, or tap Open the sample hotel on the Building plan card: it is the same job.

Sample designs: names, sizes and clients are made up. Prices are BidRidge's starting rates; set your own. The designers check against common guidelines (IRC, NKBA and the makers' published numbers) to help you catch mistakes. They don't replace your building department or the manufacturer's installation instructions: verify with them.