Code figures here are starting defaults to verify with your building department (and an engineer where the design calls for one): frost depth 42″ (Anchorage), footings 6″ thick at least, steps 7 3/4″ risers and 10″ treads at most and least, a handrail at 4 risers, anchor bolts 6′ o.c. Nothing here is an engineered or stamped design.
Concrete: the slab's change (recess taken out, the slab thickened under it where it would get thinner than the minimum set) and the concrete of pits, pads and blockout infill. Edge forms (screed rails) at recess edges. Not an engineered design.
Control joints by the slab settings (default 30 x the thickness, 15 ft at most, panels 1.5 to 1: NRMCA CIP 6, Joints in Concrete Slabs on Grade). The accessibility checks use the 2010 ADA Standards (US Access Board text, sections cited on each line) and flag what to look at; they don't certify a design. Dowels, vapor retarder class, FF / FL and products come from the project's drawings and specs.
Footings, walls and their bars come from the structural drawings: the designer counts them (marks, sizes, spacing, laps and hooks as typed) and never sizes them. Wall forms are the contractor's means and methods: pressure and spacing from the published tables cited in the checks, flagged for a qualified engineer past them (29 CFR 1926.703(a)(1)).
Elevated slabs come from the structural drawings: the designer counts them (deck profile, thickness, reinforcing, studs, pour stops, openings as typed; concrete from the profile geometry) and never designs a slab, a deck, a shore or a bar. Deck profiles are typical: verify with the deck maker's data.
Makes a template with a Concrete scope: one row per slab (exact area, CY with thickened edges, base, forms, joints, isolation, the bar list, vapor barrier, PEX) and one per footing, wall, pier group and set of steps (CY, forms, bars, anchor bolts, frost insulation), plus the pours, pump, season, dowels, saw-cuts, handrails, drains, manifolds, a notes block and the drawing set, bar list and buy list. BidRidge prices them at your rates.
Open in BidRidge hands the template to the BidRidge web app in this browser (bid-ridge.com/app) and opens its Templates screen. For the Android app, use Save BidRidge template and import the file.
One row a product the design uses, under its MasterFormat section (03 30 00, 07 26 00, 03 15 16...). Generic: type the product and manufacturer the specification calls for.
The project also saves in this browser as you work.